Honeywell Water Heater Igniter Not Working: Quick Fixes & Tips

If your Honeywell water heater igniter isn’t working, check for power supply issues or a faulty igniter. These are common problems.

A malfunctioning igniter in a Honeywell water heater can be frustrating, especially when hot water is needed. Various issues can cause the igniter to fail, such as power supply problems, a faulty igniter, or issues with the gas supply. Regular maintenance can help prevent these problems.

Understanding the potential causes and solutions can save time and money. Checking the power supply and ensuring the gas valve is open are simple initial steps. If the problem persists, consulting a professional technician is advisable. Proper care and timely intervention can ensure your water heater functions efficiently.

Table of Contents

Common Issues

Experiencing problems with your Honeywell water heater igniter can be frustrating. Identifying common issues can help you troubleshoot and resolve the problem quickly. Below are some of the most frequently encountered issues.

Faulty Igniter

A faulty igniter is one of the most common problems. If the igniter doesn’t spark, the heater won’t light. This could be due to wear and tear or a manufacturing defect.

Here are some signs of a faulty igniter:

  • No clicking sound
  • Visible damage or corrosion
  • Heater fails to start

Replacing a faulty igniter can often solve the problem. Always refer to the user manual for proper instructions.

Loose Connections

Loose connections can also prevent the igniter from working. Check all wires and connectors to ensure they are secure.

Common connection issues include:

  • Loose wire connections
  • Disconnected wires
  • Corroded connectors

Fixing loose connections can restore your heater’s functionality. Make sure to turn off the power before inspecting.

Common Issue Possible Solution
Faulty Igniter Replace the igniter
Loose Connections Secure all wires and connectors

Safety Precautions

When dealing with a Honeywell water heater igniter not working, safety is crucial. Following proper safety measures prevents accidents and ensures smooth repairs. Below are essential safety precautions to follow.

Turn Off Gas Supply

Before inspecting your water heater, turn off the gas supply. This step is vital to avoid gas leaks and potential explosions. Follow these steps:

  1. Locate the gas shut-off valve near your water heater.
  2. Turn the valve to the ‘OFF’ position.
  3. Ensure the valve is securely closed by checking for gas smells.

Turning off the gas supply eliminates the risk of gas-related accidents.

Disconnect Power

Next, disconnect the power to your water heater. Water heaters can have electric components that pose shock risks. Here’s how to do it safely:

  • Locate the circuit breaker panel in your home.
  • Identify the breaker linked to your water heater.
  • Switch the breaker to the ‘OFF’ position.

Always verify that the power is off before proceeding. Use a voltage tester if necessary to double-check.

Following these safety precautions ensures a safe environment to fix the igniter issues.

Tools Needed

Experiencing issues with your Honeywell Water Heater Igniter not working? Fixing it yourself can save time and money. Let’s gather the essential tools needed for the job. Proper tools ensure a smooth and efficient repair process.

Screwdrivers

One of the most important tools you’ll need is a set of screwdrivers. These are used to open the heater’s access panel. Ensure you have both Phillips and flathead screwdrivers. This will help you handle different types of screws.

A magnetic screwdriver can be particularly useful. It keeps screws from falling into hard-to-reach places. A screwdriver set with various sizes also comes in handy.

Multimeter

A multimeter is another crucial tool for this repair. It helps check the electrical continuity and voltage of the igniter. This tool will help you diagnose if the igniter is receiving power. It can also tell if there are any electrical issues.

Ensure the multimeter is set to the correct setting. Follow the manufacturer’s instructions for accurate readings. A digital multimeter is often easier to read and more precise.

Using these tools will make fixing your Honeywell Water Heater Igniter easier and more efficient. Make sure you have them ready before you start the repair process.

Honeywell Water Heater Igniter Not Working: Quick Fixes & Tips

Credit: www.reddit.com

Inspecting The Igniter

Experiencing issues with your Honeywell water heater igniter? This guide will help you inspect the igniter. Follow these steps to diagnose the problem. Start with a visual check and proceed to test for continuity.

Visual Check

First, perform a visual inspection of the igniter. Look for any obvious signs of damage:

  • Cracks
  • Burn marks
  • Broken wires

Ensure the igniter is clean and free from debris. A dirty igniter may not function properly. If you see any visible damage, the igniter likely needs replacement.

Testing For Continuity

Next, test for continuity using a multimeter. Follow these steps:

  1. Turn off the water heater and unplug it.
  2. Remove the igniter from the water heater.
  3. Set your multimeter to the continuity setting.
  4. Touch the multimeter probes to the igniter terminals.

If the multimeter beeps, the igniter has continuity. If not, the igniter is faulty and needs replacing.

Ensure you perform these steps safely. Use protective gloves and follow the manufacturer’s guidelines.

Cleaning The Igniter

Is your Honeywell water heater igniter not working? Cleaning the igniter can often solve the problem. A clean igniter ensures efficient operation. Follow these steps to clean it properly.

Removing Debris

Start by turning off the water heater. Ensure safety first. Locate the igniter. It is usually near the burner assembly. Carefully inspect for any visible debris.

  • Use a soft brush to remove loose debris.
  • Be gentle to avoid damaging the igniter.
  • A vacuum cleaner can help remove stubborn particles.

Ensure all debris is cleared. This helps in proper igniter function.

Using Appropriate Cleaners

After removing debris, use appropriate cleaners for a thorough clean.

Type of Cleaner Usage
Isopropyl Alcohol Effective for removing grime.
Soft Cloth Ideal for applying the cleaner.
  1. Apply isopropyl alcohol to a soft cloth.
  2. Gently wipe the igniter.
  3. Ensure no residue remains.

Using appropriate cleaners ensures the igniter is spotless. A clean igniter ensures your water heater works efficiently.

Checking The Wiring

Honeywell Water Heater Igniter Not Working

Is your Honeywell Water Heater Igniter not working? The wiring might be the culprit. Checking the wiring is crucial for diagnosing issues. Follow these simple steps to inspect and fix the wiring.

Inspecting Connections

First, turn off the power to the water heater. Safety is key. Next, open the access panel to expose the wires. Look for any disconnected or damaged wires. Use a flashlight if needed.

Check the wire terminals for any corrosion. Corroded terminals can cause a poor connection. If you find corroded terminals, clean them carefully. Use a wire brush for better results.

Step Action
1 Turn off power
2 Open access panel
3 Inspect wires and terminals
4 Clean corroded terminals

Tightening Loose Wires

Next, check for any loose wires. Loose wires can disrupt the igniter’s function. Use a screwdriver to tighten any loose connections. Ensure all wires are securely attached to their terminals.

  • Identify loose wires
  • Tighten with screwdriver
  • Secure all connections

After tightening, double-check all connections. Make sure everything is secure. This will help ensure your igniter works properly.

Replacing The Igniter

Honeywell Water Heater Igniter Not Working: Replacing the Igniter

If your Honeywell water heater igniter is not working, it might be time for a replacement. Replacing the igniter is a straightforward process. Follow these steps to ensure your water heater is back in top condition.

Removing The Old Igniter

The first step is to remove the old igniter. Here is how to do it:

  1. Turn off the gas supply to ensure safety.
  2. Locate the access panel on your water heater.
  3. Remove the screws and open the access panel.
  4. Disconnect the igniter wires carefully.
  5. Remove the screws holding the igniter in place.
  6. Gently pull out the old igniter.

Installing The New Igniter

After removing the old igniter, it’s time to install the new one. Follow these steps:

  1. Insert the new igniter into the slot.
  2. Secure it with the screws you removed earlier.
  3. Reconnect the igniter wires.
  4. Close the access panel and secure it with screws.
  5. Turn the gas supply back on.
  6. Test the new igniter to ensure it works properly.

Replacing the igniter on your Honeywell water heater can seem daunting. With these steps, you can complete it with ease. Ensure you follow safety precautions. Your water heater will be up and running in no time.

Honeywell Water Heater Igniter Not Working: Quick Fixes & Tips

Credit: m.youtube.com

Testing The New Igniter

Testing the new igniter for your Honeywell water heater ensures it functions correctly. Follow these steps to restore power and check ignition.

Restoring Power

First, ensure the power to the water heater is off. This step is crucial for safety. Locate the circuit breaker and flip the switch to the off position.

After installing the new igniter, restore power to the water heater. Flip the circuit breaker switch to the on position. The power is now restored, and you can proceed to the next step.

Checking Ignition

With power restored, observe the igniter. Look for a spark or glow. This indicates that the igniter is working. If there is no spark or glow, you may have a faulty igniter.

Ensure the gas valve is open. This allows gas to flow to the igniter. Listen for the sound of gas flowing. If you do not hear gas, check the valve and connections.

If the igniter sparks and the gas is flowing, the burner should ignite. Observe the burner for a steady blue flame. A yellow or flickering flame indicates a problem.

If the burner ignites and the flame is steady, your water heater is functioning correctly. If not, you may need to troubleshoot further or consult a professional.

Step Action
1 Turn off the circuit breaker
2 Install the new igniter
3 Restore power
4 Check for spark or glow
5 Open the gas valve
6 Listen for gas flow
7 Observe the burner flame

By following these steps, you ensure your Honeywell water heater igniter works correctly. Proper testing helps maintain a reliable and efficient water heater.

Resetting The System

Experiencing issues with your Honeywell water heater igniter can be frustrating. Thankfully, resetting the system can often resolve these problems. Below, you will find two effective methods to reset your water heater: using the reset button and power cycling. These steps are simple and can be done quickly, helping you get your water heater back in working order.

Using The Reset Button

Most Honeywell water heaters come with a built-in reset button. This button is usually located on the control panel. Follow these steps to reset the system using the reset button:

  • Turn off the power supply to the water heater.
  • Locate the reset button on the control panel.
  • Press and hold the reset button for 10 seconds.
  • Release the button and wait for the system to reset.
  • Turn the power supply back on.

Using the reset button can often resolve minor issues. If the problem persists, you may need to try power cycling the unit.

Power Cycling

Power cycling your water heater is another effective method. This involves turning the power off and then back on again. Follow these steps to power cycle your Honeywell water heater:

  1. Turn off the power supply to the water heater.
  2. Wait for at least 30 seconds.
  3. Turn the power supply back on.

Power cycling can help reset the system and resolve many issues. Always ensure your water heater is properly connected and receiving power.

Both methods are quick and simple. These steps can help you get your water heater back in working order without needing professional help.

Thermocouple Issues

Experiencing issues with your Honeywell water heater igniter? The problem might lie with the thermocouple. This small but crucial component ensures your heater operates safely. Let’s explore common thermocouple issues and how to fix them.

Identifying Problems

The thermocouple is a safety device. It detects if the pilot light is lit. If the pilot goes out, the thermocouple stops gas flow. This prevents potential gas leaks. Here are signs your thermocouple might be failing:

  • Pilot light won’t stay lit.
  • No hot water.
  • Frequent pilot light outages.

If you notice these signs, it’s time to inspect the thermocouple.

Replacing The Thermocouple

Replacing the thermocouple is a straightforward task. Follow these steps:

  1. Turn off the gas supply.
  2. Remove the burner assembly.
  3. Disconnect the old thermocouple from the gas valve.
  4. Install the new thermocouple.
  5. Reassemble the burner.
  6. Turn the gas supply back on.
  7. Light the pilot and test the heater.

Here’s a table summarizing the tools you’ll need:

Tool Purpose
Wrench Loosen and tighten connections
Screwdriver Remove screws from the burner assembly
New Thermocouple Replacement part

With these tools, you can easily replace the thermocouple. This should restore your water heater’s functionality.

Gas Supply Problems

Honeywell Water Heater Igniter Not Working: Gas Supply Problems

If your Honeywell water heater igniter is not working, gas supply issues could be the cause. Ensuring a proper gas supply is crucial for the heater’s operation. Let’s explore the steps to identify and fix these problems.

Checking Gas Flow

First, verify that gas is flowing to your water heater. Follow these steps:

  1. Locate the gas valve.
  2. Ensure the valve is in the ‘On’ position.
  3. Inspect the pilot light. A steady flame indicates gas flow.

If there’s no flame, the gas flow might be interrupted. Check for any blockages in the gas line.

Inspecting Gas Lines

Next, inspect the gas lines for leaks or damages. Leaks can prevent gas from reaching the heater. Follow these steps:

  1. Turn off the gas supply.
  2. Mix a solution of soap and water.
  3. Apply the solution to the gas lines.
  4. Turn the gas back on.
  5. Look for bubbles, which indicate leaks.

If you find a leak, contact a professional to repair it. Do not attempt to fix gas leaks yourself.

Issue Solution
No gas flow Ensure the gas valve is on
Pilot light off Check for blockages
Gas line leaks Contact a professional

Ensuring a proper gas supply can help your Honeywell water heater function effectively.

Pilot Light Troubles

Honeywell Water Heater Igniter Not Working: Pilot Light Troubles

Is your Honeywell water heater not working? The pilot light may be the issue. A faulty pilot light can mean no hot water. It’s important to address this problem quickly. Below, we’ll guide you through the steps to fix it.

Relighting The Pilot

First, ensure your heater is off. Look for the gas valve and turn it to “Off.” Wait for five minutes to let any gas clear out. Turn the gas valve to “Pilot.” Hold down the red button on the valve. Use a lighter to ignite the pilot.

Keep holding the red button for 60 seconds. This will keep the pilot light on. Release the button and set the valve to “On.” Your pilot light should now stay lit. If it goes out again, there may be a bigger issue.

Adjusting The Flame

A weak flame can cause the pilot light to go out. Check the flame color. It should be blue with a yellow tip. If it’s not, you need to adjust it. Locate the flame adjustment screw on the pilot assembly.

Use a screwdriver to turn the screw. Turn it slowly to increase or decrease the flame. Adjust until the flame is strong and blue. If the flame doesn’t change, there might be a blockage. Clean the pilot tube with a thin wire or needle.

These steps should help with your Honeywell water heater. Proper maintenance ensures your water heater lasts longer.

Control Module Faults

Honeywell Water Heater Igniter Not Working: Control Module Faults

The control module is the brain of your Honeywell water heater. If the igniter stops working, the control module might be faulty. This section will guide you through diagnosing and replacing the control module.

Diagnosing Issues

First, check for error codes on the control module display. These codes provide clues about the fault.

Error Code Meaning
4 Flashes Ignition Failure
5 Flashes Flame Sensor Fault

Next, inspect the wiring connections. Ensure all wires are secure and in good condition.

  • Check for any visible damage to wires.
  • Ensure connectors are firmly attached.

If the error code and wiring seem fine, test the control module with a multimeter. This will help confirm if it’s the source of the problem.

Replacing The Module

If the control module is faulty, replace it with a new one. Follow these steps:

  1. Turn off the power to the water heater.
  2. Remove the access panel to reach the control module.
  3. Disconnect the wiring from the old control module.
  4. Remove the screws holding the module in place.
  5. Install the new control module and secure it with screws.
  6. Reconnect the wiring according to the manual.
  7. Replace the access panel and restore power.

After installation, reset the water heater and check for proper operation.

Sensor Malfunctions

Experiencing issues with your Honeywell water heater igniter? Often, the culprit is sensor malfunctions. Sensors play a crucial role in ensuring the heater functions correctly. A malfunctioning sensor can disrupt the entire system. Here, we discuss how to address these issues effectively.

Testing Sensors

Start by testing the sensors. Use a multimeter to check for continuity. No continuity indicates a faulty sensor. Follow these steps:

  1. Turn off the power supply to the heater.
  2. Remove the access panel to locate the sensors.
  3. Disconnect the sensor wires.
  4. Use the multimeter to test for continuity.

If the multimeter shows no continuity, the sensor is defective.

Cleaning Or Replacing

Sometimes, sensors only need cleaning. Follow these steps:

  • Turn off the power supply.
  • Remove the sensor carefully.
  • Use a soft brush to clean the sensor.
  • Reinstall the sensor and restore power.

If cleaning doesn’t work, consider replacing the sensor. Refer to the manufacturer’s guidelines for compatible replacements.

Regular maintenance helps in preventing sensor malfunctions. Always ensure sensors are clean and in good working condition. This enhances the longevity of your Honeywell water heater.

Ventilation Problems

A Honeywell water heater igniter not working can often be traced back to ventilation problems. Proper ventilation is crucial for the safe and efficient operation of your water heater. If the unit cannot vent correctly, it may fail to ignite or operate. Below, we explore two key aspects of ventilation issues and how to address them: Clearing Blockages and Ensuring Proper Venting.

Clearing Blockages

Blockages in the ventilation system can prevent your water heater from igniting. These blockages can be caused by debris, dust, or even small animals. Regularly check and clean the vent pipes to ensure there are no obstructions.

  • Inspect the vent pipes for any visible blockages.
  • Use a brush or vacuum to remove any dust or debris.
  • Check for signs of animal nests or other obstructions.

If you find any blockages, clear them immediately. This can improve the performance of your water heater. Regular maintenance can prevent future issues.

Ensuring Proper Venting

Proper venting allows the water heater to expel gases safely. Improper venting can lead to ignition failure. Ensure that the vent pipes are correctly installed and free from damage.

  1. Check that all vent connections are secure.
  2. Ensure the vent pipes are free from cracks or corrosion.
  3. Verify that the venting system meets local building codes.

If you notice any issues with the venting system, it might be necessary to consult a professional. Proper venting is essential for the safe operation of your water heater. Regular inspections can help maintain the efficiency of your unit.

Honeywell Water Heater Igniter Not Working: Quick Fixes & Tips

Credit: tylertork.com

Temperature Settings

Understanding the temperature settings on your Honeywell water heater is essential. It ensures your water heater operates efficiently and provides the desired water temperature. Temperature settings play a crucial role in the performance of your water heater igniter.

Adjusting The Thermostat

Adjusting the thermostat on your Honeywell water heater is straightforward. Locate the thermostat dial usually found on the front of the unit. Turn the dial to your preferred temperature setting. Ensure you do not set it too high to avoid scalding risks.

Here is a simple guide to adjusting the thermostat:

  1. Turn off the power to the water heater.
  2. Locate the thermostat dial on the water heater.
  3. Turn the dial to your desired temperature.
  4. Turn the power back on to the water heater.

Optimal Temperature Range

Setting the water heater to the right temperature is vital. The optimal temperature range ensures safety and energy efficiency. According to experts, the ideal temperature setting is between 120°F and 140°F.

Here is a quick reference table for optimal temperature settings:

Temperature (°F) Purpose
120°F Safe for most households, energy-efficient
130°F Effective for killing bacteria, slightly higher energy use
140°F Recommended for homes with dishwashers without pre-heating

Setting the thermostat within this range ensures your water heater operates efficiently. It also helps prevent the igniter from overworking.

Regular Maintenance

Maintaining your Honeywell water heater igniter ensures it runs smoothly. Regular maintenance helps prevent unexpected breakdowns. It also extends the lifespan of the unit. Below are some essential maintenance tips to keep your water heater igniter in top shape.

Cleaning Schedule

Cleaning your Honeywell water heater igniter is crucial. Dirt and debris can cause malfunctions. Follow this cleaning schedule to keep it in perfect condition:

Task Frequency
Inspect igniter for dirt Monthly
Clean igniter with a soft brush Every 3 months
Check burner area for debris Monthly
Wipe down exterior surfaces Monthly

Consistent cleaning keeps your igniter functioning properly. It reduces the risk of unexpected failures.

Annual Inspections

Conducting annual inspections is vital for your water heater igniter. A professional can identify potential issues early. This proactive approach saves money and stress. Here’s what an annual inspection should include:

  • Check igniter for signs of wear and tear.
  • Test ignition system for proper operation.
  • Inspect connections for corrosion or damage.
  • Ensure ventilation is clear and unobstructed.
  • Verify gas supply and pressure levels.

Scheduling these inspections ensures your unit runs efficiently. It also helps avoid costly repairs and increases its lifespan.

Professional Help

If your Honeywell Water Heater Igniter is not working, seeking professional help might be necessary. This ensures that your water heater is repaired correctly and safely. Knowing when to call a technician and how to choose a reliable service can save you time and money.

When To Call A Technician

Sometimes, troubleshooting on your own may not resolve the issue. Here are signs that indicate you should call a professional:

  • Igniter not sparking even after resetting the system.
  • Strange noises coming from the water heater.
  • Persistent error codes on the control panel.
  • Gas smell around the water heater.
  • Frequent pilot light outages.

If you notice any of these issues, contact a technician immediately. They have the expertise to diagnose and fix the problem safely.

Choosing A Reliable Service

Selecting the right service provider is crucial. Follow these tips to ensure you choose a reliable technician:

  1. Check Reviews: Look for online reviews and testimonials.
  2. Verify Credentials: Ensure the technician is licensed and insured.
  3. Ask for Referrals: Get recommendations from friends or family.
  4. Compare Quotes: Get multiple estimates to compare prices.
  5. Check Experience: Ensure they have experience with Honeywell water heaters.

These steps help you find a trustworthy service provider. This ensures your Honeywell water heater is in good hands.

Preventive Measures

Honeywell Water Heater Igniter Not Working: Preventive Measures

Keeping your Honeywell water heater igniter in good condition is essential. Simple preventive measures can save time and money. Regular maintenance ensures a longer lifespan. Avoid common mistakes and follow these tips.

Avoiding Common Mistakes

  • Do not ignore warning signs: Strange noises or flickering lights indicate issues.
  • Avoid using dirty fuel: Clean fuel prevents clogging and damage.
  • Ensure proper ventilation: Blocked vents cause overheating and igniter failure.
  • Avoid overloading: Excessive use can strain the system.
  • Do not neglect regular checks: Regular inspections identify issues early.

Ensuring Longevity

Ensuring the longevity of your Honeywell water heater igniter involves a few simple steps. First, schedule annual maintenance. Regular check-ups by a professional help catch problems early. Clean the igniter and surrounding components regularly.

Keep the area around your water heater clean and dust-free. Dust can clog the system and cause malfunction. Use a soft brush to remove dust from vents and other openings. Replace worn-out parts as needed. Ignoring worn-out parts can lead to bigger issues.

Use high-quality, clean fuel to avoid clogging and damage. Check the fuel lines for leaks or blockages. Fuel quality directly affects the performance of your igniter. Follow the manufacturer’s guidelines for fuel type and quality.

Preventive Measure Action Required
Annual Maintenance Schedule professional check-ups
Regular Cleaning Clean igniter and components regularly
Quality Fuel Use high-quality, clean fuel
Check Fuel Lines Inspect for leaks and blockages

Troubleshooting Tips

A malfunctioning Honeywell water heater igniter can disrupt your daily routine. To help you fix the issue quickly, we have compiled some troubleshooting tips. Follow these steps to get your water heater back in working condition.

Step-by-step Guide

Follow this simple guide to troubleshoot your Honeywell water heater igniter:

  1. Turn off the power supply to the water heater.
  2. Inspect the igniter for visible damage or wear.
  3. Clean the igniter with a soft brush or cloth.
  4. Check the wiring connections for any loose or broken wires.
  5. Ensure the gas supply valve is open and functioning.
  6. Test the igniter by turning the power back on.

Common Fixes

Here are some common fixes to resolve igniter issues:

  • Replace the Igniter: If the igniter is damaged, replace it with a new one.
  • Check the Thermocouple: Ensure the thermocouple is properly connected and not faulty.
  • Inspect the Gas Valve: Make sure the gas valve is working correctly and not obstructed.
  • Examine the Flame Sensor: Clean the flame sensor to ensure it detects the flame properly.
  • Control Board: Verify the control board is functioning and not displaying error codes.

By following these troubleshooting tips, you can often resolve the issue without professional help. Always ensure safety by turning off power and gas supplies before working on the water heater.

Frequently Asked Questions

Why Is My Honeywell Water Heater Not Igniting?

The igniter might be faulty, or the gas supply could be interrupted.

How Do I Reset My Honeywell Water Heater?

Turn the power off for 10 seconds, then back on.

What Causes A Water Heater Igniter To Fail?

Common causes include a faulty igniter, gas valve issues, or wiring problems.

Can A Faulty Igniter Be Repaired?

Most often, replacing the igniter is more effective than repairing it.

How Can I Test My Honeywell Igniter?

Use a multimeter to check for continuity in the igniter.

Is It Safe To Replace The Igniter Myself?

If you are confident in your skills, yes. Otherwise, contact a professional.

How Long Do Water Heater Igniters Last?

Typically, igniters last 3-5 years, depending on usage and maintenance.

What Tools Are Needed To Replace An Igniter?

You’ll need a screwdriver, a multimeter, and possibly a wrench.

Can Gas Supply Issues Affect The Igniter?

Yes, insufficient gas supply can prevent the igniter from working.

Where Can I Buy A Replacement Igniter?

Replacement igniters are available at hardware stores or online retailers.

Conclusion

Fixing a Honeywell water heater igniter can be simple with the right steps. Regular maintenance ensures long-lasting performance. Always check connections and clean parts to avoid issues. If problems persist, consulting a professional is wise. Keep your water heater running efficiently for comfort and convenience.

Leave a Comment